Product Description
RDL FP-MP1 Studio Quality Microphone Preamplifier with Phantom - Terminal Block & XLR
Overview
The FP-MP1 is the ideal choice in most applications requiring a preamp. RDL's exclusive low-noise discrete circuitry produces studio quality low noise performance in an economical preamplifier. The XLR and plug-in terminal block connections make the FP-MP1 perfect for both rack-mounted hardwired installations and remote use with standard audio cables. A front-panel switch permits the installer to direct phantom voltage to the input connectors. This 3-position switch provides 24V, 12V or phantom OFF. A second switch selects the input gain range thereby permitting the connection of standard or high output level microphones.
Features
- Professional Studio-Quality Low-Noise Performance
- Switchable Internal Phantom Voltage
- XLR and Terminal Block Connections
- Selectable Input Level Ranges
- Adjustable Gain with Dual-LED VU Metering
- Ultra-Compact All Metal Construction
- Convenience of RDL® FLAT-PAKs™
Specifications
Input Impedance: 3 kΩ (balanced)
GAIN (4 ranges):
MIN: 19 dB to 38 dB (switch-selectable)
LOW: 26 dB to 45 dB (switch-selectable)
MED: 36 dB to 55 dB (switch-selectable)
HIGH: 46 dB to 65 dB (switch-selectable)
MED: 36 dB to 55 dB (switch-selectable)
HIGH: 46 dB to 65 dB (switch-selectable)
Input Clipping Level: +4 dBu (at MIN gain)
Headroom: 20 dB (above +4 dBu
Low-Cut Filter: 80 Hz, 6 dB/Octave (switch-selectable)
Phantom Voltages: 12 V, 24 V (switch-selectable)
Buildout Standard: IEC 61938: 2013
CMRR: > 60 dB
Frequency Response: 20 Hz to 20 kHz (± 0.2 dB)
THD + N: < 0.1% (+4 dBu, all gain settings)
IMD: < 0.1%
Noise (below +4 dBu):
< -70 dB (60 dB gain, 20 Hz to 20 kHz)
< -72 dB (60 dB gain, “A-Weighted”)
< -80 dB (50 dB gain, 20 Hz to 20 kHz)
< -80 dB (50 dB gain, 20 Hz to 20 kHz)
Equivalent Input Noise: < -130 dB (gain + residual noise below +4 dBu)
Connector type: XLR female (input); XLR male (output); 5 position plug-in terminal block (input and output)
Audio Level Indicators (2):
Red LED: Output level > +4 dBu
Green: -10 to +4 dBu (variable intensity)
Ambient Operating Environment: 0° C to 50° C
Power Requirement: GROUND-REFERENCED, 24 Vdc @ 100 mA
Dimensions: Height: 1.42 in 3.61 cm; Width: 3.25 in. 8.26 cm; Length: 4.64 in. 11.79 cm