Product Description
Leviton Greenmax Command Module RPM16-316
GreenMAX® Main Command Module for Relay Panel with 16-port low voltage input card, 100-277VAC, 50/60Hz, LumaCAN 3
GreenMAX Main Command Module complete with 70W power supply, Main Processor, LumaCAN 3, with 16 Low Voltage inputs. 100-277VAC 50/60Hz.
The Leviton GreenMAX® Relay Panel line offers features and performance not available from any competing product on the market today. For increased reliability and durability, GreenMAX Cabinets and Relay Modules have a 25,000A Short Circuit Current Rating (SCCR) at 277VAC. Native communication network protocols – BACnet/IP, Ethernet, and LumaCAN – are built into each GreenMAX Command Module (processor) to offer unparalleled connectivity. No additional parts or adapters are needed to communicate with other products utilizing these protocols. For increased flexibility, the modular GreenMAX system includes separate Cabinet enclosures, Command Modules (processor, power supply, and low voltage inputs), Relay Insert Panels, Relay Modules, and a Handheld Display Unit (HDU).
DESCRIPTION The Leviton GreenMAX® Relay Command Module (processor) has native communication network protocols – BACnet/IP, Ethernet and LumaCAN3 built in to offer unparalleled connectivity. By utilizing these protocols, no additional parts or adapters are needed to communicate with other products. The relay command modules include the systems processor, power supply and low voltage input cards. For increased flexibility, the modular GreenMAX system includes separate cabinet enclosures, command modules, relay insert panels, relay modules and a Handheld Display Unit (HDU). For easier manageability and accessibility, Leviton ships empty cabinet enclosures separately from the electronic components. This makes the cabinets lighter and easier to handle, requiring less effort to install. To further minimize handling and damage, Leviton can ship the electronic components later in the project schedule or as required.
FEATURES • The relay command module is the processor and power supply of the GreenMAX system and optionally includes a low voltage remote input card for analog devices • Native communication network protocols— BACnet/IP, Ethernet and LumaCAN3 are built into each relay command module to offer unparalleled connectivity; no additional devices are needed to communicate with other products utilizing these protocols • Can control any combination of local (mounted in the cabinet) and remote relays up to a maximum total of 48 relays • Relay command module functions include: - Daylight harvesting - Demand response - Dimming - Partial ON - Partial OFF - Stairwell control - Timed switches - Blink warn
APPLICATIONS • Heavy retrofit applications • New construction projects • Government facilities • Office buildings • Hospitals/medical offices • Universities • Restaurants • Large campuses • Parking garages • Any location requiring daylight harvesting and demand response
PRODUCT DATA GreenMAX® Relay Command Module SPECIFICATIONS Electrical • Power Supply Input: 70W (max), 100-277VAC single phase 50/60 Hz input, 24VDC output • Non-volatile memory and micro SD card protect programming during blackouts Wiring • Internal: factory pre-wired and tested • System communications: - LumaCAN3 requires standard CAT6 network cabling - Low voltage Class 2 wiring connects input cards to control devices such as occupancy sensors, low voltage switches and photocells - Hard-wired dedicated emergency input is provided in each cabinet and requires an external normally open (N/O) contact closure; the cabinet provides the source of low voltage for this circuit; individual relay response to the emergency signal can be programmed to open, close or ignore • Line Voltage: - Feed for relay command module (control electronics) and load wiring only - Requires single phase hot, neutral and ground connection • LumaCAN Network: - CAT6 cable - RJ45 connectors - Wiring configuration (EIA/TIA 568B) • Power must be injected into LumaCAN3 cable approximately every 900 feet • For additional network power, use a remote low voltage cabinet or additional relay cabinets. Each of these components contain a full power supply. Network Connections • Maximum LumaCAN3 communication network segment length is 1,600 feet from end of line termination to end of line termination; longer network lengths can be achieved with the use of a LumaCAN3 repeater • Ethernet connectivity is native to each command module - Ethernet can be used to connect BACnet/IP system - Ethernet can be used to bridge between runs of LumaCAN3 to extend network length • BACnet/IP is native to each relay command module in the complete system - BACnet/IP must be run to each cabinet and connect to the Ethernet port Physical • Installs into a GreenMax Enclosure and can only be used with a GreenMAX lighting control system Environmental • Ambient Temperature Range: 32-122°F (0-50°C) • Relative Humidity: <90% non-condensing Listings • UL508, UL924, cUL, can be used to comply with 2016 Title 24, Part 6 occupancy/vacancy sensing, 0-10V dimming, daylight harvesting, partial-ON, partial-OFF, scheduling, demand response, and receptacle control requirements • Listing and ratings only apply when installed in a GreenMAX enclosure Warranty • Relay modules backed by a 5-year warranty
CAT. NO. DESCRIPTION Relay Command Module (includes power supply with main processor unit), option 24VDC Low Voltage Input Card
- RPM00-300 Main Relay Command Module, 100-277VAC, 50/60 Hz, no inputs, LumaCAN3
- RPM08-308 Main Relay Command Module with 8-Port Low Voltage Input Card, 100-277VAC, 50/60 Hz, LumaCAN3
- RPM16-316 Main Relay Command Module with 16-Port Low Voltage Input Card, 100-277VAC, 50/60 Hz, LumaCAN3 O