Product Description
ILC 2R7C 20Amp, SPST, 120/277VAC latching relay
2R7C includes the following:
- Status Contacts: 7= without status
- Connector: C= Molex push-on connector
2R series relays are designed to be the longest lasting,most reliable relays available. By incorporating a unique single moving contact, both endurance and reliability are significantly enhanced. These relays have been tested to handle 200,000 full load cycles and 1,000,000 no load cycles. They have two high quality nickel-silver contacts that can handle
- Single moving contact design
- Made in the USA
- Rated 20 Amps @ 120, 277 and 347VAC
- SCCR rated to 18,000 Symmetrical Amps
- Latching contacts
- Easy mounting with push-on connectors
- Isolated status feedback
General Information • UL Listed • Mounts in standard 1 ⁄2” K.O. .825” - .875” diameter, 14 or 16 gauge material • Operates in any position
Line Voltage Characteristics • Contacts: SPST Maintained (permanent magnet latching) • Terminals:2 terminals, 2 back wiring holes per terminal feedthrough wiring • Screw-actuated clamps for use with #14-10AWG solid or stranded copper wire only
Low Voltage Characteristics • Split coil: 1 ⁄2 for “ON”, 1 ⁄2 for “OFF” • Compatible with standard interface drivers • Operating voltage: — 18 – 30 VAC rectified — 12 – 24 VDC filtered • Duty rating: Momentary • Minimum activating pulse time: 17 milliseconds • Coil Impedance: 68 – 73 ohms at 60Hz, 50 – 60 ohms DC resistance • Switching power required for each 2R relay is: — 2.2 VA per relay at 24 VAC rectified — 175 mA per relay at 12 VDC — 350 mA per relay at 24 VDC
Physical: • Mounts in standard 1 ⁄2” K.O. .825” – .875” • Operates in any position
Electrical: • 120, 277 or 347 VAC • Motor Loads — 1 Hp @120VAC • SCCR Rating*: 18,000 Symmetrical Amperes • 20 amp Ballast 120, 277 or 347 VAC • Resistive loads: 20 amps 120, 277 or 347 VAC
Connectors: • Leads available in plain wire (no connector), C connector (5-pin female connector), EZ connector (quick disconnect terminals for standard .187” x .020” male tabs)
Operating Environment: • Location Interior Space • Operating 0° to 60° C (32° to 140° F) Temperature • Relative 10% to 95% Humidity Non-condensing • Atmosphere Non-explosive, Non-corrosive • Vibration Stationary application NEMA Level A
Certifications: • UL • FCC Approval for commercial and residential use
“Suitable for use on a circuit capable of delivering not more than 10,000 rms Symmetrical Amperes, 120 Volts maximum when protected by 50A maximum RK5 fuses or a 50A circuit breaker having an interrupting rating not less than 10,000 rms Symmetical Amperes, 277 VAC maximum. Suitable for use on a circuit capable of delivering not more than 18,000 rms Symmetrical Amperes, 277 volts AC maximum, when protected by a 20A maximum RK5 fuse having an interruption rating not less than 18,000 rms Symmetrical Amperes, 277VAC maximum.