Product Description
ETC P-CCS Paradigm Central Control Server Rev1, Repair
Part# 7180A1150
1. This is for the repair of an existing item. |
2. Once you place your order, then we will email you with an RMA# and shipping instructions so that you can ship your item out for repair. |
3. Please note that it may take up to 1-business day for us to send you the RMA# and shipping instructions. |
4. You will pay for the cost of outbound shipping on the repair. You can also decide the speed at which you want to ship the item out for repair. |
5. Please provide us with any technical notes about the issues that you are having with this product, so that they can be address during the repair of the unit. |
6. The repair will take approximately 1-2 weeks from the date of receipt of the item. |
7. The repaired unit will then be shipped back to you via the outbound shipping method that you select with this order. (Free, Ground, 2-Day, Overnight). |
8. Please call us at 1-866-457-5937 for any technical support questions. |
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The Paradigm Central Control Server scales up Paradigm systems to master the most complex lighting venues. By integrating a native BACnet communication system and incorporating ETC Virtual and Large-Format Touchscreens, the Paradigm Central Control Server achieves the most comprehensive building-wide control.
Please note the picture is for illustrative purposes only.
APPLICATIONS
• Hotels
• Museums
• Casinos
• Conference centers
• Theme parks
FEATURES
• Designed for use with Unison Paradigm Architectural Control Systems
• Provides a central interface and control for multiple discrete control systems
• Supports collection of measured and calculated energy usage
• Configurable Demand Response integration for load shedding
• Virtual Touchscreen Stations (VTS) and large-format touchscreen integration
• Native BACnet IP interface for integration with Building Management Systems (BMS)
• Supports BACnet event scheduling to ensure lighting events occur on time, even when the BACnet system is offline
• Provides network time synchronization for all ETC lighting products in the system
• Provides persistent error logging for the entire lighting control system
• LightDesigner Access: Web browser interface for easy modification, activation and monitoring of your system
REGULATORY AND COMPLIANCE
• ETL and cETL Listed
• CE Marked
SPECS
FUNCTIONAL
• Supports up to 64 Paradigm Architectural Control Processors
• System
- Multi-user LiveControl and LiveEdit
- Network Time Protocol for real-time clock synchronization supporting real and astronomical events
- Addition of processors to a system proportionately increases the overall capacities
- Failure of a single Paradigm ACP does not prevent continuous operation of the remaining connected systems
- Logging of system error messages using Syslog format
- Support for ANSI / ASHRAE 135.1 BACnet IP protocol with up to 1000 each analog inputs, binary inputs, analog outputs, and binary outputs
• Diagnostics
- Event logs are stored in persistent memory using Syslog format
- Standard log shall store a history of recent activity
• Configuration Data
- Remote upload from a connected PC running LightDesigner or another connected Paradigm ACP
- Stored in persistent memory
- Remote retrieval from a connected PC running LightDesigner
• Scalability
- Supports up to 12 Paradigm ACPs in a single project (pcf)
- Control Server project (spcf)
- Supports network time service for synchronization of time and timed events
- Supports multiple Paradigm projects on the same Ethernet network with logical limits between systems
- Allows for timed event configuration from an external source using BACnet IP
- Provides remote use of up to 32 individually customized Virtual Touchscreen application s(VTS)
• Web User Interface
- Internal web server accessible via the primary Ethernet port
- Activate and deactivate presets - Schedule global timed events (add/edit/delete)
- Displays status information and log files
- Configuration of server settings (date, time, network)
• California Title 20/24 Compliant
DEMAND RESPONSE
• Supports external triggering of utility initiated Demand Response
• Trigger may be RS232, UDP or BACnet
• Energy reduction may occur by:
- Zone(s)/ Channel(s)
- Group(s)
- Space(s)
ENERGY MANAGEMENT
• Supports measured energy usage for compatible products using Net3 networking. Contact ETC for compatible products.
• Supports calculated energy usage of all zones/channels controlled by connected Paradigm Architectural Control Processor(s)
• Displays energy usage and trends on user interfaces including:
- 7” Touchscreen (P-TS7)
- 18” Touchscreen (P-TS18)
- Touchscreen Interface (P-TSI)
- Virtual Touchscreen (P-VTS)
- P-CCS web interface
• Historical data is stored for up to ten years with data granularity based on the age of the data
• Energy usage is recorded in 5 minute intervals
MECHANICAL
• Designed for use in Unison Paradigm Architectural Control Systems
• Self-contained electronics assembly
• Enclosure made from 16-gauge formed steel and finished in a black, fine-texture powder coat paint
• 1U, 19-inch equipment rack mountable
• Backlit power switch with blue LED status indicator
• Standard connections for the following interfaces:
- Front panel USB connection
- RJ45 Ethernet connection for Lighting Network
- RJ45 Ethernet connection for Building Lighting Network (BACnet and VTS)
- Four Rear panel USB connections
- One RS232 Serial port (diagnostics only)
• Internal hard drive for storage of configuration data
ELECTRICAL
• 100-240VAC, 50/60 Hz power input
• Microprocessor-based technology to provide system wide, multi-project lighting and building controls
• Two IEEE802.3u-compliant Ethernet connections
- Primary port for connection to lighting systems for Virtual Touchscreen Interfaces
- Secondary port for connection to BACnet systems and Virtual Touchscreen Interfaces
• Automatic restoration to previous power state when returning from power loss
• System configuration and programming information stored in persistent memory
• Support of ESTA ANSI E1.17 Advanced Control Networks
THERMAL
• Ambient room temperature: 0-40°C / 32-104°F
• Ambient humidity: 5-95% non-condensing