Product Description
Doug Fleenor Design DMX2MPX DMX to NSI Microplex Converter
The DMX to Microplex interface is capable of converting DMX512 to NSI, Leprecon or Lightronics versions of Microplex. Since each of these manufactures uses unique timings the DMX to Microplex interface provides jumpers to configure the Microplex output.
DMX512 input is received via 5-pin male XLR connector. Microplex output is via a 3 pin female XLR connector. A "pass-thru" 5-pin female XLR is also provided for the DMX signal. LED indicators display DMX input signal, power and a Mimic of Microplex channel 1. A three digit thumbwheel switch is provided to set the starting address as well as access single channel diagnostic mode (601-728).
Specs
Input signal: 250 Kilobaud, 0.2 volts minimum, 12 volts maximum
Input circuit: ESD protected EIA-485 transceiver (LT1785)
Input connector: Gold plated 5 pin male (Neutrik D-1 series)
Input pass through: Gold plated 5 pin female (Neutrik D-1 series) All five pins are passed through
Output circuit: Hi-speed operational amplifier (LF347) (low current mode) Push – Pull transistors (2N3904 & 2N3906) (high current mode)
Output connector(s): Gold plated 3 pin female (Neutrik D-1 series)
Output Pinout:
- Pin 1 Common
- Pin 2 N/C
- Pin 3 signal
Power input: 100 - 120 volts, 50/60 hertz, 12 watts (208 - 240 volt optional)
Color: Top, bottom and sides: Silver hammer tone Front and back: Black
Size and weight: 1.7"H × 6.5"D × 6.5"W, 2.7 pounds (19” rack adapter available)